1kv Interlocked Armored Electrical Teck 90 Power Cable Multi-Conductor W/ Ground Aluminum/Copper Electric Building Wire
Contact Supplier
Product Highlights
- Versatile Conductor Options: Available with bare copper or aluminum wire cores for diverse electrical needs.
- Customizable Core Count: Offered in 2, 3, 4, or 5 core configurations to match specific circuit requirements.
- Flexible Voltage Ratings: Rated for 600V, 1000V, and 5kV to suit low, medium, and high voltage applications.
- Hazardous Location Rated: FT4 flame resistance and HL rating for safe use in hazardous industrial environments.
- Comprehensive Certifications: ISO, CCC, CE, UL, TUV, KEMA, and CSA approved for global market compliance.
- Durable Aluminum Armor: Interlocked aluminum armor provides mechanical protection for direct burial and trays.
- Custom Color Options: Standard black PVC jacket with optional colors available upon request.
Product Attributes
- Customization
- Available
- Application
- Construction, Underground, Industrial, Power Station
- Voltage
- Low and Medium Voltage Cable
- Model NO.
- teck 90 cable
- Current
- DC & AC
- Insulation Material
- PVC
- Sheath Material
- PVC
- Material Shape
- Round Wire
- Wire Core Material
- Bare Copper/Aluminum Wire
- Certification
- ISO, CCC, CE
- Model
- PVC Cables
- Brand
- Huatong
- Conductor
- RW90
- Core
- 2 3 4 5
- Armor
- Aluminum Alloy
- Rated Voltage
- 600V 1000V 5kv
- Standard
- C-S-a C22 No. 131
- Products Name
- Teck 90, Teck 90 Hl
- Market
- The Us, Canada, Australia Ect
- Type
- Power Cable
- Certificate
- cUL
- Conductor Material
- Copper or Aluminum
- Shield
- with or Without
- Transport Package
- Steel-Wooden Drum, Steel Drum
- Specification
- 14AWG TO 1000MCM
- Trademark
- RNEDA
- Origin
- China
- HS Code
- 8544492100
- Production Capacity
- 1000m/Month
- Package Size
- 100.00cm * 100.00cm * 100.00cm
- Package Gross Weight
- 500.000kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of 1kv Interlocked Armored Electrical Teck 90 Power Cable Multi-Conductor W/ Ground Aluminum/Copper Electric Building Wire
Find Similar Products
Product Description
Hebei huatong wires&cables Group Co.,ltd.
Largest cable manufacture in north China
19 years export experience
With UL,TUV,KEMA,CE,BV,PSB,SABS,GL,NK,KR,ABS ..products certifications
ISO9001,ISO14001,OHSAS18001 system certifications
With authorities testing report
CNAS approval laboratory
TECK 90 CU 1000V NON-SHIELDED XLPE POWER CABLE
1000V, Non-Shielded, XLPE Insulation, FT4, -40°C, HL (Hazardous Locations), 90°C
Construction:
- Conductor:Class B stranded compressed copper in accordance with ASTM B3 and ASTM B8
- Insulation:XLPE (Cross Linked Polyethylene), Minimum Average Thickness: 4/0 = 0.08 inches (2.03 mm), 250 kcmil to 1000 kcmil = 0.090 inches (2.3 mm), 90°C
- Concentric Bonding Conductors:Class B, concentric bare copper wire serve
- Binder:Polypropylene Separator
- Inner Jacket:Black PVC, Minumum average thickness - 4/0 = 0.050" (1.27mm), 250 kcmil to 1000 kcmil = 0.060" (1.5 mm)
- Armor:Aluminum Interlocked Armour (AIA)
- Overall Jacket:Black PVC (optional colours available), Minimum Thickness: 4/0 to 400 kcmil = 0.050 inches (1.3 mm), 500 kcmil to 1000 kcmil = 0.060 inches (1.5 mm)
Armoured Control 16 AWG 600V
| No. of Conductor | AWG Size | Approximate Diameter (Over) | Net Weight w/ Armour | ||||
| Cond. | Bond Wire | Inner Jacket (in.) | Armour (in.) | Outer Jacket (in.) | LB/MFT | LB/MFT | |
| 2 | 16 | 16 | 0.336 | 0.536 | 0.650 | 177 | 264 |
| 4 | 16 | 16 | 0.386 | 0.586 | 0.700 | 217 | 323 |
| 6 | 16 | 16 | 0.446 | 0.686 | 0.798 | 264 | 393 |
| 8 | 16 | 16 | 0.545 | 0.785 | 0.897 | 300 | 447 |
| 12 | 16 | 16 | 0.626 | 0.826 | 0.950 | 407 | 605 |
| 20 | 16 | 16 | 0.749 | 0.949 | 1.070 | 545 | 811 |
| 30 | 16 | 16 | 0.942 | 1.172 | 1.280 | 811 | 1206 |
| 50 | 16 | 16 | 1.149 | 1.379 | 1.480 | 1141 | 1697 |
| No. of Conductors | AWG Size | Insulation Thickness (in.) |
Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) | LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
||
| 2 | 14 | 14 | 0.030 | 0.130 | 0.360 | 0.580 | 0.670 | 39 | 58 | 195 | 290 |
| 4 | 14 | 14 | 0.030 | 0.130 | 0.420 | 0.640 | 0.720 | 68 | 101 | 256 | 381 |
| 6 | 14 | 14 | 0.030 | 0.130 | 0.500 | 0.720 | 0.800 | 95 | 142 | 316 | 471 |
| 8 | 14 | 14 | 0.030 | 0.130 | 0.570 | 0.790 | 0.870 | 117 | 174 | 373 | 555 |
| 12 | 14 | 14 | 0.030 | 0.130 | 0.680 | 0.900 | 0.990 | 176 | 262 | 511 | 761 |
| 20 | 14 | 14 | 0.030 | 0.130 | 0.910 | 1.130 | 1.210 | 285 | 424 | 789 | 1174 |
| 30 | 14 | 14 | 0.030 | 0.130 | 1.060 | 1.280 | 1.360 | 402 | 599 | 1015 | 1511 |
| 50 | 14 | 14 | 0.030 | 0.130 | 1.300 | 1.520 | 1.600 | 661 | 984 | 1463 | 2178 |
| No. of Conductors | AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) | LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
||
| 2 | 12 | 14 | 0.030 | 0.150 | 0.400 | 0.620 | 0.700 | 55 | 82 | 228 | 340 |
| 4 | 12 | 14 | 0.030 | 0.150 | 0.470 | 0.690 | 0.770 | 96 | 143 | 293 | 436 |
| 6 | 12 | 14 | 0.030 | 0.150 | 0.590 | 0.810 | 0.890 | 137 | 204 | 416 | 619 |
| 8 | 12 | 14 | 0.030 | 0.150 | 0.640 | 0.860 | 0.940 | 177 | 264 | 492 | 732 |
| 12 | 12 | 14 | 0.030 | 0.150 | 0.790 | 1.010 | 1.100 | 261 | 389 | 653 | 972 |
| 20 | 12 | 14 | 0.030 | 0.150 | 1.010 | 1.230 | 1.320 | 424 | 631 | 986 | 1468 |
| 30 | 12 | 14 | 0.030 | 0.150 | 1.180 | 1.400 | 1.490 | 630 | 938 | 1320 | 1965 |
| 50 | 12 | 14 | 0.030 | 0.150 | 1.450 | 1.670 | 1.770 | 1044 | 1553 | 2055 | 3058 |
Multiconductor 10 AWG 600V
| o. of Conductors | AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) | LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
||
| 2 | 10 | 12 | 0.030 | 0.180 | 0.450 | 0.670 | 0.750 | 87 | 130 | 275 | 410 |
| 4 | 10 | 12 | 0.030 | 0.180 | 0.555 | 0.740 | 0.830 | 150 | 223 | 413 | 615 |
| 6 | 10 | 12 | 0.030 | 0.180 | 0.660 | 0.880 | 0.960 | 217 | 323 | 515 | 766 |
| 10 | 10 | 12 | 0.030 | 0.180 | 0.860 | 1.080 | 1.160 | 348 | 518 | 828 | 1232 |
| 15 | 10 | 12 | 0.030 | 0.180 | 1.000 | 1.220 | 1.300 | 512 | 762 | 1084 | 1613 |
| 25 | 10 | 12 | 0.030 | 0.180 | 1.250 | 1.470 | 1.550 | 835 | 1243 | 1612 | 2399 |
| 40 | 10 | 12 | 0.030 | 0.180 | 1.490 | 1.710 | 1.810 | 1321 | 1966 | 2278 | 3390 |
Control Composite 3 Power & 3 Control Conductors 600V
| 14 AWG | ||||||||||
AWG Size |
Insulation Thickness (in.) |
Approximate Diameter (Over) | Copper Content |
Net Weight w/ Armour | ||||||
Control |
Power |
Bond Wire |
Inner Jacket (in.) |
Armour (in.) |
Outer Jacket (in.) |
LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
|
| 14 | 12 | 14 | 0.300 | 0.560 | 0.780 | 0.860 | 114 | 170 | 356 | 530 |
| 14 | 8 | 10 | 0.450 | 0.690 | 0.950 | 1.000 | 208 | 310 | 541 | 805 |
| 14 | 4 | 8 | 0.450 | 0.890 | 1.140 | 1.250 | 485 | 722 | 972 | 1446 |
| 14 | 1 | 6 | 0.550 | 1.140 | 1.390 | 1.500 | 911 | 1356 | 1539 | 2290 |
| 14 | 2/0 | 6 | 0.550 | 1.320 | 1.570 | 1.710 | 1378 | 2051 | 2150 | 3199 |
| 14 | 4/0 | 4 | 0.550 | 1.550 | 1.800 | 1.940 | 2167 | 3225 | 3080 | 4583 |
| AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Control | Power | Bond Wire | Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) |
LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
|
| 12 | 10 | 12 | 0.030 | 0.665 | 0.865 | 0.979 | 180.2 | 268.0 | - 431 | 641 |
| 12 | 6 | 8 | 0.060 | 0.914 | 1.134 | 1.250 | 361.6 | 538.0 | 822 | 1223 |
| 12 | 2 | 6 | 0.060 | 1.026 | 1.246 | 1.362 | 772.3 | 1149.0 | 1307 | 1944 |
| 12 | 1/0 | 6 | 0.080 | 1.263 | 1.483 | 1.603 | 1143.3 | 1701.0 | 1840 | 2737 |
| AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) | LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
|
| 4 | 6 | 0.060 | 0.350 | 0.490 | 0.730 | 0.810 | 211 | 314 | 410 | 610 |
| 2 | 6 | 0.060 | 0.420 | 0.560 | 0.780 | 0.870 | 286 | 426 | 510 | 760 |
| 1/0 | 4 | 0.080 | 0.530 | 0.690 | 0.910 | 1.000 | 458 | 682 | 760 | 1130 |
| 3/0 | 3 | 0.080 | 0.630 | 0.810 | 1.030 | 1.120 | 685 | 1020 | 1080 | 1610 |
| 250 | 2 | 0.090 | 0.750 | 0.990 | 1.210 | 1.290 | 980 | 1459 | 1490 | 2210 |
| 350 | 1 | 0.090 | 0.815 | 1.120 | 1.360 | 1.445 | 1340 | 1994 | 1910 | 1910 |
| 500 | 1/0 | 0.090 | 0.925 | 1.200 | 1.475 | 1.560 | 1841 | 2604 | 2510 | 3740 |
| 750 | 2/0 | 0.090 | 1.160 | 1.370 | 1.590 | 1.690 | 2570 | 3825 | 3510 | 5230 |
Two Conductor 1000V
| AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Inner Jacket (in.) |
Armour (in.) | Outer Jacket (in.) |
LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
|
| 14 | 14 | 0.045 | 0.170 | 0.430 | 0.650 | 0.730 | 39 | 58 | 219 | 326 |
| 10 | 12 | 0.045 | 0.210 | 0.510 | 0.730 | 0.810 | 86 | 128 | 291 | 433 |
| 6 | 8 | 0.060 | 0.310 | 0.720 | 0.940 | 1.020 | 215 | 320 | 556 | 827 |
| 3 | 6 | 0.060 | 0.380 | 0.930 | 1.150 | 1.230 | 415 | 618 | 905 | 1347 |
| 1 | 6 | 0.080 | 0.490 | 1.120 | 1.340 | 1.420 | 612 | 911 | 1235 | 1838 |
| 2/0 | 6 | 0.080 | 0.580 | 1.280 | 1.500 | 1.580 | 922 | 1372 | 1660 | 2470 |
| 4/0 | 4 | 0.080 | 0.690 | 1.480 | 1.700 | 1.790 | 1466 | 2182 | 2350 | 3497 |
| 300 | 4 | 0.090 | 0.760 | 1.765 | 2.005 | 2.115 | 2018 | 3003 | 3341 | 4972 |
| 400 | 3 | 0.090 | 0.850 | 1.945 | 2.185 | 2.295 | 2687 | 3999 | 4147 | 6171 |
| 750 | 1 | 0.090 | 1.160 | 2.450 | 2.670 | 2.790 | 4941 | 7353 | 6872 | 10226 |
Three Conductor 1000V
| AWG Size | Insulation Thickness (in.) | Approximate Diameter (Over) | Copper Content | Net Weight w/ Armour | ||||||
| Cond. | Bond Wire | Insul. (in.) |
Insul. (in.) |
Armour (in.) | Outer Jacket (in.) | LB/ MFT |
KG/ KM |
LB/ MFT |
KG/ KM |
|
| 14 | 14 | 0.045 | 0.170 | 0.470 | 0.670 | 0.760 | 52 | 77 | 261 | 388 |
| 10 | 12 | 0.045 | 0.210 | 0.590 | 0.790 | 0.880 | 124 | 185 | 374 | 557 |
| 6 | 8 | 0.060 | 0.310 | 0.780 | 1.030 | 1.130 | 300 | 447 | 724 | 1078 |
| 3 | 6 | 0.060 | 0.380 | 0.970 | 1.220 | 1.300 | 582 | 866 | 1136 | 1691 |
| 1 | 6 | 0.080 | 0.490 | 1.210 | 1.440 | 1.540 | 866 | 1288 | 1593 | 2371 |
| 2/0 | 6 | 0.080 | 0.580 | 1.380 | 1.650 | 1.770 | 1327 | 1974 | 2225 | 3311 |
| 4/0 | 4 | 0.080 | 0.690 | 1.600 | 1.860 | 1.980 | 2109 | 3138 | 3207 | 4772 |
| 300 | 4 | 0.090 | 0.760 | 1.885 | 2.125 | 2.235 | 2961 | 4406 | 4460 | 6637 |
| 400 | 3 | 0.090 | 0.850 | 2.075 | 2.315 | 2.455 | 3948 | 5875 | 5719 | 8511 |
| 600 | 2 | 0.090 | 1.005 | 2.410 | 2.650 | 2.790 | 5868 | 8733 | 7948 | 11828 |
| 1000 | 1 | 0.090 | 1.310 | 3.080 | 3.280 | 3.440 | 9612 | 14303 | 12184 | 18130 |
Single Conductor 1kV Teck 90 is a C-S-A approved armoured cable for Industrial and Commercial applications. FT4, -40C, HL, AG14 and 90°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, hazardous locations, continuous rigid cable supports, and concrete encaseable. CSA AG14 Acid Gas compliance.
- -40°C - CSA Cold Bend and Impact Temperature
- -25°C - Min. Installation Temperature
- 90°C - Max. Continuous Operating Temperature
- 140°C for Emergency Overload Temperature
-
ASTM B3 Standard Specification for Soft or Annealed Copper Wire - ASTM B8 Concentric-Lay-Stranded Copper Conductors
- CSA C22.2 No. 131 Type TECK 90 Cable
- CSA C22.2 No. 174 Cables in Hazardous Locations
- CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
- CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
- CSA HL - for Hazardous Locations rating
- CSA SUN RES - for Sunlight Resistant rating
- CSA AG14 - Acid Gas Compliance
- ICEA S-96-659 (NEMA WC 71) 2001-5000 V Nonshielded Cables
- IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
- FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
Sample Print Legend:






About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259137". Items marked "" are certified.
Company Profile
Hebei Huatong Wires & Cables Group Co., Ltd.: A Global Leader in the Cable Industry
Founded in 1993, Hebei Huatong Wires & Cables Group Co., Ltd. Has grown from a modest enterprise into a modern, comprehensive, and large-scale leader in the domestic wire and cable industry. Over the past three decades, the company has achieved remarkable development, establishing itself as a trusted name in the global market. With a strong commitment to innovation, quality, and sustainability, Huatong Cable has become a key player in the wire and cable industry, serving a wide range of sectors and international markets.
Comprehensive Product Portfolio
Huatong Cable offers an extensive range of high-quality products designed to meet the diverse needs of various industries. Our product portfolio includes:
---Low Voltage (LV) and Medium Voltage (MV) Power Cables: Up to 35kV, these cables are engineered for reliability and efficiency in power transmission and distribution.
---Building Wires and Fixed Wiring Wires: Ideal for residential, commercial, and industrial applications, ensuring safe and efficient electrical installations.
---Underground Cables: Designed for durability and performance in subterranean environments, these cables are widely used in urban infrastructure projects.
---Rubber Series Cables: Including welding cables, crane cables, mining cables, and silicon rubber cables, these products are built to withstand harsh conditions and heavy-duty applications.
---Submersible Pump Cables: Specially designed for use in submersible pumps, these cables offer excellent waterproof and corrosion-resistant properties.
---Control Cables and Instrument Cables: Used in automation and control systems, these cables ensure precise signal transmission and reliable performance.
---Elevator Cables: Engineered for the demanding requirements of elevator systems, these cables provide flexibility and durability.
---Shipboard Cables: Approved for use in marine environments, these cables meet stringent safety and performance standards.
---Solar Cables: Designed for photovoltaic systems, these cables offer high UV resistance and long-term reliability.
---Vehicle Cables: Used in automotive and transportation applications, these cables ensure optimal performance and safety.
---Aerial Bundled Cables (ABC): Ideal for overhead power distribution, these cables are widely used in rural electrification projects.
---Conductors: High-quality conductors for various applications, ensuring efficient power transmission.
Global Market Presence
Huatong Cable's products have gained extensive influence and a stellar reputation in both domestic and international markets. Our cables are widely used in key projects across the globe, including in the United States, Canada, Holland, Italy, Russia, Britain, Australia, New Zealand, Ethiopia, Ghana, Algeria, South Africa, Congo, the Middle East, and Southeast Asia. This global reach is a testament to the quality, reliability, and performance of our products.
Complete Certification System
---Product Certifications: We have obtained UL, cUL, CSA, TUV, CE, BV, KEMA, SABS, and PSB certifications, ensuring that our products meet international standards for safety and performance.
---System Certifications: We are proud to hold ISO 9001 (Quality Management System), ISO 14001 (Environmental Management System), and OHSAS 18001 (Occupational Health and Safety Management System) certifications. These certifications reflect our dedication to product quality, environmental sustainability, and the health and safety of our workers.
---UL Certifications: Our UL-certified products include XHHW, THW/THHN, SER/SEU/MHF/UD, MV90/MV105, TC/TC-ER, PV, AC, MC, welding cables, SOOW/SJOOW, DLO, and mining cables.
---Shipboard Cable Approvals: Our shipboard cables have been approved in eight countries, including China, Japan, South Korea, the USA, Germany, the UK, Norway, and France.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- Tangshan, Hebei, China
Our Production Capability & Technical Expertise
- Main Products
- Power Cable, Electric Cable, Mv Cable, LV Cable, Esp Cable, Service Entrance Wire, Mining Cable, Solar/PV Cable, Instrumentation Cable, Wind Power Cable
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Number of Foreign Trading Staff
- 39
-
Overseas Agent/Branch
- No
FAQ
- What conductor materials are available?
- We offer both bare copper and aluminum wire cores to suit different project requirements.
- Can the cable be customized for specific voltages?
- Yes, the cable is available in 600V, 1000V, and 5kV ratings depending on your needs.
- Is the cable suitable for hazardous locations?
- Yes, it is rated for hazardous locations (HL) with FT4 flame resistance and CSA AG14 acid gas compliance.
- Are there options for the number of cores?
- Yes, we provide 2, 3, 4, or 5 core configurations for multi-conductor applications.
- Does the cable come in different colors?
- The standard jacket is black PVC, but optional colors are available upon customization.
- What certifications does the product hold?
- The cable holds ISO, CCC, CE, UL, TUV, KEMA, and CSA certifications for global compliance.
- Is OEM and ODM service available?
- Yes, we provide both OEM and ODM services for customized manufacturing solutions.
Send your message to this supplier
People who viewed this also viewed
-
US$0.90-1.00 / Foot
-
US$1.90-2.00 / Meter
-
US$2.20-2.50 / Meter
-
US$0.123-0.13 / Foot
-
US$7.00-15.00 / Meter
Find Similar Products By Category
- Supplier Homepage
- Products
- cUL&CSA certificate cables
- TECK90
- 1kv Interlocked Armored Electrical Teck 90 Power Cable Multi-Conductor W/ Ground Aluminum/Copper Electric Building Wire
Related Categories
Hot Searches
- China Cable Factories
- HDMI Cable Factories
- Video Cable Factories
- Control Cable Factories
- Y 90 Electrical Insulation
- Armored Cable Wire
- 90 Degree Plug
- Copper Wire Armoured Cable
- Y 90 Electric Tape
- Top 10 Cable
- Cable Trends
- Teck Cable Wire Bulkbuy