4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable

Product Details
Customization: Available
Application: Construction, Underground, Industrial, Power Station, Mining
Voltage: Low and Medium Voltage Cable

Industry-leading Audited Factory

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Customization from Designs
The supplier provides design based customization services
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
CCC
to see all verified strength labels (29)
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
  • 4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
Find Similar Products

Basic Info.

Model NO.
TECK90
Current
DC & AC
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Red Copper Wire
Certification
RoHS
Model
Teck90
Brand
Rneda
Transport Package
Soft Packing, Standard Export Drums
Specification
16AWG--500MCM
Trademark
RNEDA
Origin
China
HS Code
8544492100
Production Capacity
1000km/Month

Product Description

600V TECK90 Cable


4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable

  1. Conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
  2. Insulation: Cross-linked Polyethylene (XLPE) Type RW90
Color: Black, white for 2 conductors;
      Black ,red, blue for 3 conductors;
      Black, red, blue, white for 4 conductors.
  1. Bonding conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
  2. Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
  3. Armour: Aluminum Interlock Armour (AIA);
  4. Outer-jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
 
Application:
Suitable for use in exposed or concealed wiring in dry or wet locations, in
ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried.
Suitable for use in hazardous locations: Class I - Groups A, B, C and D, Class II - Groups E, F and G, Class III - All Groups

Standard: CSA C22.2 No. 131, Type TECK90 cable;
                  CSA C22.2 No. 38, Thermoset insulated wires and cables (Type RW90)
       FT4 - Flame Test (70,000 BTU/Hr - Vertical Tray Flame Test)

Working temperature: -40ºC to +90ºC

Voltage: 600V

CUL file No: E466697

Marking on the surface of cable:
HT CABLES 600V 3/C 1/0AWG+6AWG CU/XLPE/PVC/AIA/PVC TECK90 ARMOURED CABLE  2023/01****M

Packing Length: 300m, 600m or other length. Plastic drums or plywood drums.


Technical data: 600V
Phase Conductor Bonding Conductor Phase conductor single wire numbers Nominal thickness of XLPE insulation Approx. diameter after assembly Nominal thickness of inner sheath Approx. Diameter armoured Nominal thickness of outer sheath Approx. O.D. of cable
Cores AWG or Kcmil AWG or Kcmil Nos. mm mm mm mm mm mm
2 14 14 7 0.76 6.7 1.14 14.1 1 16
2 12 14 7 0.76 7.7 1.14 15.1 1 17
2 10 12 7 0.76 8.9 1.14 16.3 1 18
2 8 10 7 1.14 11.4 1.52 19.5 1 22
2 6 8 7 1.14 13.1 1.52 21.3 1 23
2 4 8 7 1.14 15.4 1.52 23.5 1 26
2 3 6 7 1.14 16.6 1.52 24.7 1 27
2 2 6 7 1.14 18.2 2.03 27.3 1 29
2 1 6 19 1.4 20.8 2.03 29.9 1 32
2 1/0 6 19 1.4 22.7 2.03 31.8 1 34
2 2/0 6 19 1.4 24.7 2.03 33.9 1 36
2 3/0 4 19 1.4 27.1 2.03 36.2 1 38
2 4/0 4 19 1.4 29.7 2.03 38.9 1.2 41
2 250 4 37 1.65 33 2.03 42.2 1.2 45
2 300 4 37 1.65 35.6 2.03 44.7 1.2 47
2 350 3 37 1.65 37.9 2.79 48.6 1.2 51
2 400 3 37 1.65 40.1 2.79 50.8 1.2 53
2 450 3 37 1.65 42.2 2.79 52.8 1.2 55
2 500 3 37 1.65 44 2.79 54.7 1.2 57
2 550 3 37 2.03 47.5 2.79 58.2 1.5 61
2 600 2 61 2.03 49.4 2.79 60.1 1.5 63
2 650 2 61 2.03 51 2.79 61.7 1.5 65
2 700 2 61 2.03 52.7 2.79 63.4 1.5 66
2 750 2 61 2.03 54.2 2.79 64.9 1.5 68
 
Phase Conductor Bonding Conductor Phase conductor single wire numbers Nominal thickness of XLPE insulation Approx. diameter after assembly Nominal thickness of inner sheath Approx. Diameter armoured Nominal thickness of outer sheath Approx. O.D. of cable
Core AWG or Kcmil AWG or Kcmil Nos. mm mm mm mm mm mm
3 14 14 7 0.76 7.3 1.14 14.7 1.0 17
3 12 14 7 0.76 8.3 1.14 15.7 1.0 18
3 10 12 7 0.76 9.7 1.14 17.0 1.0 19
3 8 10 7 1.14 12.3 1.52 20.4 1.0 22
3 6 8 7 1.14 14.2 1.52 22.3 1.0 24
3 4 8 7 1.14 16.6 1.52 24.8 1.0 27
3 3 6 7 1.14 17.9 2.03 27.1 1.0 29
3 2 6 7 1.14 19.6 2.03 28.8 1.0 31
3 1 6 19 1.40 22.4 2.03 31.6 1.0 34
3 1/0 6 19 1.40 24.5 2.03 33.6 1.0 36
3 2/0 6 19 1.40 26.7 2.03 35.8 1.0 38
3 3/0 4 19 1.40 29.2 2.03 38.4 1.2 41
3 4/0 4 19 1.40 32.1 2.03 41.3 1.2 44
3 250 4 37 1.65 35.7 2.03 44.8 1.2 47
3 300 4 37 1.65 38.4 2.79 49.1 1.2 51
3 350 3 37 1.65 40.9 2.79 51.6 1.2 54
3 400 3 37 1.65 43.3 2.79 54.0 1.2 56
3 450 3 37 1.65 45.5 2.79 56.2 1.2 59
3 500 3 37 1.65 47.5 2.79 58.2 1.5 61
3 550 3 37 2.03 51.3 2.79 62.0 1.5 65
3 600 2 61 2.03 53.4 2.79 64.1 1.5 67
3 650 2 61 2.03 55.1 2.79 65.8 1.5 69
3 700 2 61 2.03 56.9 2.79 67.6 1.5 71
3 750 2 61 2.03 58.6 2.79 69.3 1.5 72
 
Phase Conductor Bonding Conductor Phase conductor single wire numbers Nominal thickness of XLPE insulation Approx. diameter after assembly Nominal thickness of inner sheath Approx. diameter armoured Nominal thickness of outer sheath Approx. O.D. of cable
Core AWG or Kcmil AWG or Kcmil Nos. mm mm mm mm mm mm
4 14 14 7 0.76 8.2 1.14 15.5 1.0 18
4 12 14 7 0.76 9.3 1.14 16.7 1.0 19
4 10 12 7 0.76 10.8 1.52 19.0 1.0 21
4 8 10 7 1.14 13.7 1.52 21.9 1.0 24
4 6 8 7 1.14 15.9 1.52 24.0 1.0 26
4 4 8 7 1.14 18.6 2.03 27.8 1.0 30
4 3 6 7 1.14 20.1 2.03 29.2 1.0 31
4 2 6 7 1.14 22.0 2.03 31.2 1.0 33
4 1 6 19 1.40 25.1 2.03 34.3 1.0 36
4 1/0 6 19 1.40 27.4 2.03 36.6 1.0 39
4 2/0 6 19 1.40 29.9 2.03 39.0 1.2 41
4 3/0 4 19 1.40 32.8 2.03 41.9 1.2 44
4 4/0 4 19 1.40 36.0 2.03 45.1 1.2 48
4 250 4 37 1.65 40.0 2.79 50.6 1.2 53
4 300 4 37 1.65 43.0 2.79 53.7 1.2 56
4 350 3 37 1.65 45.9 2.79 56.5 1.2 59
4 400 3 37 1.65 48.5 2.79 59.2 1.5 62
4 450 3 37 1.65 51.0 2.79 61.7 1.5 65
4 500 3 37 1.65 53.2 2.79 63.9 1.5 67
4 550 3 37 2.03 57.5 2.79 68.2 1.5 71
4 600 2 61 2.03 59.8 2.79 70.5 1.5 73
4 650 2 61 2.03 61.8 2.79 72.4 1.5 75
4 700 2 61 2.03 63.7 3.55 75.9 1.5 79
4 750 2 61 2.03 65.6 3.55 77.8 1.7 81

1000V TECK90 CABLE


4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable
    

  1. Conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
  2. Insulation: Cross-linked Polyethylene (XLPE) Type RW90
Color: Black, white for 2 conductors;
      Black ,red, blue for 3 conductors;
      Black, red, blue, white for 4 conductors.
  1. Bonding conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
  2. Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
  3. Armour: Aluminum Interlock Armour (AIA);
  4. Outer-jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
 
Application:
Suitable for use in exposed or concealed wiring in dry or wet locations, in
ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried.
Suitable for use in hazardous locations: Class I - Groups A, B, C and D, Class II - Groups E, F and G, Class III - All Groups

Standard: CSA C22.2 No. 131, Type TECK90 cable;
                  CSA C22.2 No. 38, Thermoset insulated wires and cables (Type RW90)
       FT4 - Flame Test (70,000 BTU/Hr - Vertical Tray Flame Test)

Working temperature: -40ºC to +90ºC

Voltage: 1000V 

CUL file No: E466697

Marking on the surface of cable:
HT CABLES 1000V 3/C 1/0AWG+6AWG CU/XLPE/PVC/AIA/PVC TECK90 ARMOURED CABLE  2023/01****M

Packing Length: 300m, 600m or other length. Plastic drums or plywood drums.





Technical data: 1000V
# of  Cond. Conductor Insulation Thickness Inner Approximate Diameters Approx . Approx . Copper Content
Size Jacket Net Cable
  Thickness Inner Jacket Armor Outer Jacket Weight
Power AWG or kcmil Bonding inches inches inches inches inches lb/kft lb/kft
AWG
1 350 1 0.09 0.06 1.07 1.34 1.45 1910 1386
1 500 1/0 0.09 0.06 1.2 1.48 1.59 2515 1925
1 750 2/0 0.09 0.06 1.41 1.68 1.81 3648 2815
2 12 14 0.045 0.045 0.46 0.7 0.79 272 54
2 8 10 0.045 0.06 0.59 0.82 0.93 407 136
2 6 8 0.06 0.06 0.72 0.95 1.06 545 217
3 12 14 0.045 0.045 0.5 0.74 0.82 297 75
3 10 12 0.045 0.06 0.58 0.81 0.89 381 118
3 8 10 0.045 0.06 0.63 0.86 0.94 491 189
3 6 8 0.06 0.06 0.77 1.04 1. 13 644 300
3 4 8 0.06 0.08 0.9 1. 18 1.27 924 447
3 3 6 0.06 0.08 0.96 1.24 1.33 1026 582
3 2 6 0.06 0.08 1.03 1.3 1.39 1274 710
3 1 6 0.08 0.08 1. 18 1.46 1.55 1539 876
3 1/0 6 0.08 0.08 1.26 1.53 1.65 1852 1081
3 2/0 6 0.08 0.08 1.35 1.62 1.73 2165 1342
3 3/0 4 0.08 0.08 1.45 1.73 1.84 2571 1719
3 4/0 4 0.08 0.08 1.57 1.82 1.93 3196 2132
3 250 4 0.09 0. 110 1.77 2. 12 2.25 3830 2497
3 350 3 0.09 0. 110 1.98 2.33 2.46 4990 3475
3 500 3 0.09 0. 110 2.24 2.6 2.76 6674 4891
4 8 10 0.045 0.06 0.69 0.92 1.03 583 241
4 6 8 0.06 0.08 0.9 1. 17 1.28 838 382
4 4 8 0.06 0.08 1 1.27 1.35 1122 579
4 3 6 0.06 0.08 1.09 1.36 1.44 1359 749
4 2 6 0.06 0.08 1. 15 1.42 1.5 1580 920
4 2/0 6 0.08 0.08 1.49 1.76 1.87 2711 1761
4 3/0 4 0.08 0.08 1.61 1.85 1.96 3395 2248
4 4/0 4 0.08 0. 110 1.79 2.03 2. 14 4197 2799
4 250 4 0.09 0. 110 1.95 2.3 2.42 4828 3285
4 350 3 0.09 0. 110 2. 19 2.54 2.65 6399 4578
4 500 3 0.09 0. 110 2.48 2.83 3.02 8555 6466






 

4AWG 3 Core 1000V Teck90 Armored PVC Sheath Cable

FAQ

(1).When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please

call us or tell us in your e-mail so that we will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freight

charge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7

days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express 

account orprepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.The best record we keep is

delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months

before the date you would like to get the products at your country.

contact: Mr. Steven Yun
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier