Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SHD-GC 25kv Rubber Power Portable Mine Cable with UL certification
Applications:
Type SHD-GC is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers. It is also an ex- cellent choice for shovels, draglines, dredges, cranes and marine shore-to-ship power supplies, and anytime extra-durable, flexible cable is required. Suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.
Construction:
Product Parameters
5KV
NO. OF COND. | COND. SIZE (AWG/ | COND. STRAND | NOMINAL INSULATION THICKNESS | GRD. COND. SIZE (AWG) | GRD-CHEC COND. SIZE | NOMINAL JACKETS | NOMINAL CABLE 0.D. | NET WEIGHT |
kg/ km | ||||||||
mm | mm | mm | ||||||
3 | 6 | 133 | 2.8 | 10 | 8 | 4.7 | 39.6 | 2322 |
3 | 4 | 259 | 2.8 | 8 | 8 | 4.7 | 42.7 | 2820 |
3 | 2 | 259 | 2.8 | 6 | 8 | 5.2 | 47.9 | 3639 |
3 | 1 | 259 | 2.8 | 5 | 8 | 5.2 | 49.5 | 4167 |
3 | 1/0 | 259 | 2.8 | 4 | 8 | 5.6 | 52.8 | 4807 |
3 | 2/0 | 329 | 2.8 | 3 | 8 | 5.6 | 55.9 | 5655 |
3 | 3/0 | 413 | 2.8 | 2 | 8 | 6 | 59.9 | 6660 |
3 | 4/0 | 532 | 2.8 | 1 | 8 | 6 | 63.5 | 7835 |
3 | 250 | 608 | 3 | 1/0 | 6 | 6.4 | 68.3 | 9085 |
3 | 300 | 741 | 3 | 1/0 | 6 | 6.4 | 71.4 | 10231 |
3 | 350 | 851 | 3 | 2/0 | 6 | 6.7 | 74.9 | 11600 |
3 | 500 | 1221 | 3 | 4/0 | 6 | 7.1 | 84.1 | 15499 |
8KV
NO. OF COND. | COND. SIZE (AWG/ | COND. STRAND | NOMINAL INSULATION THICKNESS | GRD. COND. SIZE (AWG) | GRD-CHECK COND. SIZE (AWG) | NOMINAL JACKET THICKNESS | NOMINAL CABLE 0.D. | NET WEIGHT | |
kg/ km | |||||||||
INCHES | mm | mm | mm | ||||||
3 | 4 | 259 | 0.15 | 3.8 | 8 | 8 | 5.2 | 49.3 | 3594 |
3 | 2 | 259 | 0.15 | 3.8 | 6 | 8 | 5.6 | 53.8 | 4554 |
3 | 1 | 259 | 0.15 | 3.8 | 5 | 8 | 5.6 | 56.1 | 5104 |
3 | 1/0 | 259 | 0.15 | 3.8 | 4 | 8 | 5.6 | 58.9 | 5700 |
3 | 2/0 | 329 | 0.15 | 3.8 | 3 | 8 | 6 | 62.5 | 6593 |
3 | 3/0 | 413 | 0.15 | 3.8 | 2 | 8 | 6.4 | 66.5 | 7738 |
3 | 4/0 | 532 | 0.15 | 3.8 | 1 | 8 | 6.4 | 69.8 | 8713 |
3 | 250 | 608 | 0.15 | 3.8 | 1/0 | 6 | 6.4 | 73.4 | 9948 |
3 | 300 | 741 | 0.15 | 3.8 | 1/0 | 6 | 6.7 | 77.2 | 11384 |
3 | 350 | 851 | 0.15 | 3.8 | 2/0 | 6 | 7.1 | 81.3 | 12739 |
3 | 500 | 1221 | 0.15 | 3.8 | 4/0 | 6 | 7.5 | 90.4 | 16757 |
15KV
NO. OF COND. | COND. SIZE (AWG/ | COND. STRAND | NOMINAL INSULATION THICKNESS | GRD. COND. SIZE (AWG) | GRD-CHECK COND. SIZE (AWG) | NOMINAL JACKET THICKNESS | NOMINAL CABLE 0.D. | NET WEIGHT |
kg/ km | ||||||||
mm | mm | mm | ||||||
3 | 2 | 259 | 5.3 | 6 | 8 | 6 | 61.2 | 5529 |
3 | 1 | 259 | 5.3 | 5 | 8 | 6 | 64 | 6042 |
3 | 1/0 | 259 | 5.3 | 4 | 8 | 6.4 | 67 | 6927 |
3 | 2/0 | 329 | 5.3 | 3 | 8 | 6.4 | 69.3 | 7783 |
3 | 3/0 | 413 | 5.3 | 2 | 8 | 6.7 | 73.7 | 8922 |
3 | 4/0 | 532 | 5.3 | 1 | 8 | 6.7 | 77.5 | 10209 |
3 | 250 | 608 | 5.3 | 1/0 | 6 | 6.7 | 78.74 | 11149 |
3 | 350 | 851 | 5.3 | 2/0 | 6 | 7.1 | 85.98 | 13194 |
3 | 500 | 1221 | 5.3 | 4/0 | 6 | 7.1 | 92.71 | 17463 |
25KV
NO. OF COND. | COND. SIZE (AWG/kcmil) | COND. STRAND | NOMINAL INSULATION THICKNESS | GRD. COND. SIZE (AWG) | GRD-CHECK COND. SIZE (AWG) | NOMINAL JACKET THICKNESS | NOMINAL CABLE 0.D. | NET WEIGHT |
kg/ km | ||||||||
mm | mm | mm | ||||||
3 | 1 | 259 | 6.6 | 5 | 8 | 6.7 | 74.93 | 7872 |
3 | 1/0 | 259 | 6.6 | 4 | 8 | 6.7 | 77.47 | 8631 |
3 | 2/0 | 329 | 6.6 | 3 | 8 | 7.1 | 81.28 | 9695 |
3 | 3/0 | 413 | 6.6 | 2 | 8 | 7.1 | 84.58 | 10737 |
3 | 4/0 | 532 | 6.6 | 1 | 8 | 7.5 | 88.9 | 12277 |
3 | 250 | 608 | 6.6 | 1/0 | 6 | 7.5 | 89.92 | 13491 |
3 | 350 | 851 | 6.6 | 2/0 | 6 | 7.5 | 96.37 | 15057 |